RELIY Product Maintenance Guide
Share
RELIY Product Maintenance Guide
1. Intermittent Operation Protection
For continuous operation of 6-8 hours, it is recommended to shut down the pump for 30 minutes to prevent motor overheating. A timer can be configured for automated management, ensuring both adequate water oxygenation and extended equipment lifespan.
2. Prompt Troubleshooting for Abnormalities
Immediate inspection is required if:
- Fountain height significantly decreases
- Water flow becomes irregular
- Motor emits humming or clicking noises
Power should be disconnected, and the filter screen and pump cavity cleaned. Check for debris such as weeds or twigs. Preventative cleaning is recommended at least once a month.
3. Long-Term Storage Procedure
For disuse exceeding 15 days:
① Power off and unplug the pump
② Drain residual water using a hose
③ Rinse the impeller and seals with clean water
④ Air-dry in a shaded place and store in a moisture-proof container
Ensure motor terminals are wrapped with waterproof tape to prevent oxidation.
4. Winterization Precautions
When water temperatures consistently drop below 5°C:
- Remove the pump from the water
- Store vertically after complete drying
- Avoid outdoor freezing conditions
- Place desiccant in storage areas
5. Seasonal Maintenance Checklist
Before spring startup annually:
✓ Inspect cable insulation for cracks
✓ Test ground fault protection
✓ Initial run should not exceed 30 minutes for observation